Heat Production and Drill Wear Following Osseous Resective Surgery: A Preliminary In Vitro SEM Study Comparing Piezosurgery and Conventional Drilling
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 38 , Issue 3
May/June 2018

Pages e33–e40


Heat Production and Drill Wear Following Osseous Resective Surgery: A Preliminary In Vitro SEM Study Comparing Piezosurgery and Conventional Drilling


Marco Tepedino, DDS/Federica Romano, DDS/Maurizio Indolfi, Eng/Mario Aimetti, MD, DDS


PMID: 29813142
DOI: 10.11607/prd.3495

The aim of this pilot in vitro study was to evaluate material wear and temperature variations after using conventional rotating bur and piezosurgical insert for osseous resective surgery in bovine bone blocks under physiologic irrigation. Wear evaluation was carried out by measuring cutting time, and wear mechanisms were analyzed by scanning electron microscopy. Time analysis showed greater material wear and higher heat production with the piezoelectric insert. However, temperatures remained below values of clinical concern even after a cutting time of 20 minutes. Conversely, bone surface appeared irregular in shape with bone debris and signs of thermal damage on the bur-drilled surface, probably due to the more traumatic action of the diamond-coated bur.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help